MeV Electron

  • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements

    The properties of a new scintillation detector system for use in dosimetry of high-energy beams in radiotherapy have been measured. The most important properties of these detectors are their hgh spatial resolution and their nearly water-equivalence.

    PHYSICS IN MEDICINE & BIOLOGY
    A.S. Beddar, T.R. Mackie, F.H. Attix | Depanment of Medical Physics, University of Wisconsin Medical School, Madison, Wl, USA
  • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration

    A minimally perturbing plastic scintillation detector has been developed for the dosimetry of high-energy beams in radiotherapy. The detector system consists of two identical parallel sets of radiation-resistant optical fibre bundles, each connected to independent photomultiplier tubes.

    PHYSICS IN MEDICINE & BIOLOGY
    A.S. Beddar, T.R. Mackie, F.H. Attix | Depanment of Medical Physics, University of Wisconsin Medical School, Madison, Wl, USA
  • A method to correct for temperature dependence and measure simultaneously dose and temperature using a plastic scintillation detector

    Plastic scintillation detectors work well for radiation dosimetry. However, they show some temperature dependence, and a priori knowledge of the temperature surrounding the plastic scintillation detectors is required to correct for this dependence.

    PHYSICS IN MEDICINE & BIOLOGY
    F.Therriault-Proulx, L.Wooton, S.Beddar | Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
  • Plastic Scintillation Detector for Dosimetric Characterization of Mobetron Ultra-High Dose Rate Electron Beam

    The purpose is to present commissioning data for the MOBETRON electron radiation therapy system (IntraOp) at ultra-high dose rate using the HYPERSCINT plastic scintillation detector. The suitability of using a plastic scintillator as an active dosimeter for commissioning measurements of an ultra-high dose rate electron beam has been demonstrated (reference dosimetry, DPP, beam penetration, linearity with number of pulses, linearity with PW and short-term output stability).

    2022 AAPM ANNUAL MEETING
    G.Famulari (1), K.Zerouali (1), O.Piron (1), JF.Aubry (1), F.DeBlois (1), JF.Carrier (2) | 1- Centre Hospitalier de l’Universite de Montreal (CHUM), Montreal, QC, CA, 2- Departement de Physique, Universite de Montreal, Montreal, QC, CA
  • Quantifying the DNA-damaging Effects of FLASH Irradiation With Plasmid DNA

    The objective is to investigate a plasmid DNA nicking assay approach for isolating and quantifying the DNA-damaging effects of ultrahigh-dose-rate (ie FLASH) irradiation relative to conventional dose-rate irradiation. The doses and dose rates were verified independently using EBT-XD Gafchromic film placed directly above the DNA-based phantom and HYPERSCINT high temporal resolution plastic scintillator placed immediately beside the DNA phantoms (both phantoms had been previously calibrated at conventional dose rates and validated at FLASH-RT dose rates).

    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY, BIOLOGY, PHYSICS
    A.Perstin (1), Y.Poirier (2), A.Sawant (2), M.Tambasco (1) | 1- Department of Physics, San Diego State University, CA, USA, 2- Department of Radiation Oncology, University of Maryland School of Medicine, Maryland, USA
  • Feasibility of Plastic Scintillator Dosimeters for FLASH Therapy

    To examine the capabilities of plastic scintillator dosimeters (PSDs) to accurately measure FLASH radiotherapy dose rates delivered with an x-ray tube.

    2020 AAPM AM
    D.Cecchi (1), F.Therriault-Proulx (2), M.Bazalova-Carter (1) | University of Victoria, Victoria, BC ,CA,, Medscint, QC, CA
  • Small field dosimetry of a Varian TrueBeam High Definition MLC linear accelerator using theHyperscint RP200 scintillation detector.

    Small field dosimetry of a Varian TrueBeam High Definition MLC linear accelerator using the Hyperscint RP200 scintillation detector.

    Purpose: To evaluate the performance of the new Hyperscint RP200 plastic scintillator for small field measurements of a Varian TrueBeam linear accelerator in comparison with the current state-of-the-art methodology in the clinic.

    Methods: Small field measurements were performed using different detectors: a diamond detector (microDiamond, PTW), a diode (Razor, IBA), a compact ion chamber (Razor, IBA), and a 1mm x 1mm
    plastic scintillation detector (Hyperscint RP200, Medscint). Correction factors based on measured field sizes, following TRS483 recommendations, were applied to all measurements. Output factors of a
    TrueBeam linear accelerator were measured for field sizes of 0.5 cm to 2 cm for jaws and MLC configurations for 6-MV, 6-MV FFF and 10-MV FFF photon beams. Output factors for different circular collimators (0.4 cm to 2 cm) were also obtained at 10-MV FFF. Scintillator measurements were compared to the small-field dosimetry methodology used clinically.

    Results: No correction factors were necessary for the plastic scintillation detector measurements. Scintillator measurements were within 1.1% of the standard methodology for all the small field geometries studied. Average relative differences were (0.3±0.5)%, (0.7±0.3)%, and (0.2±0.2)% for the 6-MV, 6-MV FFF, and 10-MV FFF, respectively. Output factors of circular field sizes down to 0.4-cm diameter were obtained with an average relative difference of (0.1±0.4)%, including a maximum difference of 0.7% for the smallest field.

    Conclusion: This new scintillation dosimetry research platform shows great promises for small field dosimetry. It has the potential to be used as part of a single-detector no-correction-factor methodology.

    2021 COMP ASM
    L.Gingras, B.Côté, F.Berthiaume, S.Lambert-Girard, D.Leblanc, L.Archambault, L.Beaulieu, F.Therriault-Proulx | CHU de Quebec – Universite Laval, QC, CA, Département de radio-oncologie et Axe Oncologie du CRCHU de Québec, QC, CA, MedScint, QC, CA